Filter Results By:

Products

Applications

Manufacturers

Resistance Test

measured in ohms is the ability of a current to conduct.

See Also: Resistance, Resistivity, Resistance Standards, Resistance Meters, Battery Internal Resistance Testers


Showing results: 481 - 495 of 1308 items found.

  • Current Transformer Tester

    CTT - ndb Technologies Inc.

    The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.

  • Manual Ranging Digital Multimeter

    HH3502 - Colluck Company Limited

    Double Injection Casing. High Accuracy (basic accuracy 0.5%). 3-1/2 digit Jumbo LCD display 2000 count with symbolic signs and back light. Manual Ranging High Voltage test up to 1000V DC and 750V AC. Higher Current test up to 20A AC/DC. Transistor test. Diode and Continuity check. Measure Resistance up to 20MΩ

  • Automated Test Systems

    SERIES 4600 - Maccor, Inc.

    The multifunction Series 4600A Automated Test Systems have been engineered to provide high capabilities for large scale single cell testing at a very economical price. Each test position: Operates independently of the other positions; Can be user programmed to run a wide range of multi-step tests; Can be user programmed to operate in steps of constant current, constant power, constant voltage, or constant resistance.

  • PRODUCTS TESTING

    ESD - MicroStat Laboratories -R.E.T.S.

    Our ESD test capabilities include resistance, resistivity, electrostatic shielding, charge generation, and charge dissipation. We routinely test flooring materials, packaging, footwear, garments, ionizers and many other ESD control products and materials. We utilize the relevant test methods and standards of the ESD Association, ANSI, ASTM, NFPA, IEST, IEC, AATCC, or our clients’ in-house specifications.

  • Corrosion Test

    Aero Nav Laboratories, Inc.

    The purpose of this test is to determine the resistance of materials and protective coatings to corrosive atmospheres when a more corrosive environment than the salt fog/spray test is required. The test is used when material is stored or operated in areas, for example, where acidic atmospheres exist, such as in industrial areas or near the exhausts of any fuel-burning device. Gases such as sulfur dioxide are used to replicate the exhausts of fuel burning devices.

  • Programmable Withstanding Voltage & Insulation Test

    LS9923 - Lisun Electronics Inc.

    LS9923 programmable withstanding voltage & insulation test system is high-performance testing device special for AC&DC Withstanding Voltage and Insulation Resistance Test, It allows setting the output voltage. The warning value,testing time and some other parameters can be set in the screen.It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the develop research.

  • Compression Test Apparatus

    CT-20 C - Lumetronics

    Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat

  • Ball Pressure Apparatus

    BP-20 - Lumetronics

    Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat.

  • Pneumatic Horizontal Shock Test System

    KRD12 series - CME Technology Co. Ltd.

    The KRD12 series shock test system is used to measure and determine the horizontal impact resistance of a product or package, and to evaluate the reliability and structural integrity of the test unit in a horizontal impact environment. The system can perform conventional half-sine wave, post-peak sawtooth wave, or trapezoid wave shock test to realize the shock energy that the product is subjected to in the actual environment, thereby improving the product or packaging structure.

  • Multi-purpose Textile Flammability Tester

    TESTEX Testing Equipment Systems Ltd.

    Multi-purpose Textile Flammability Tester, to determine the flammability resistance of textile fabrics and for the flammability test of toys and toy material. Multi-purpose Textile Flammability Tester complies with ISO 6940 (1995&2004) / 6941 (1995&2003), ISO 15025, EN71-2, etc. Please contact us for more information about flammability test method.

  • CrumpleFlex Tester

    TF117C - TESTEX Testing Equipment Systems Ltd.

    The equipment tests a tube of fabric by twisting it through 90o stretching alternately compressing the tube at the same time. After completion of the test the fabric is tested for resistance to penetration by water. CrumpleFlex Tester is fitted with electronic pre-determined counter with automatic stop at a pre-determined number of cycles, also fitted with acrylic plastic interlock safety cover.

  • Multi-purpose Textile Flammability Tester

    TESTEX Testing Equipment Systems Ltd.

    Multi-purpose Textile Flammability Tester, to determine the flammability resistance of textile fabrics and for the flammability test of toys and toy material. Multi-purpose Textile Flammability Tester complies with ISO 6940 (1995&2004) / 6941 (1995&2003), ISO 15025, EN71-2, etc. Please contact us for more information about flammability test method.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Multifunction Electrical Installations Meter

    MPI-502 - Sonel S.A.

    Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling

  • Require External Wireless Module

    Insulation Tester - MEET International Ltd.

    *Tests insulation upto 4Gohm with 4 different voltage range : 125V ; 250V ; 500V ; 1000V ( > 1mA )*Pre-set timer settable*Good / NG comparison*Auto high voltage detection*AC voltage test upto 1000V*DC voltage test upto 750V*Resistance test*Continuity check ( > 200 mA )*NCD’ Non-Contact AC Voltage Detection with patented numerical display AC signal strength ( > 50V AC )

Get Help